Digital Stethoscope in Improving the Diagnostic Accuracy of Heart Auscultation

STETOSKOP DIGITAL DALAM MENINGKATKAN AKURASI DIAGNOSTIK AUSKULTASI JANTUNG

Authors

DOI:

https://doi.org/10.35457/quateknika.v16i02.5656

Keywords:

Digital stethoscope, Signal processing, Heart rate, 12-lead ECG

Abstract

This study aims to design and implement a digital stethoscope to improve diagnostic accuracy in cardiac auscultation. Conventional stethoscopes have limitations in sound sensitivity, noise reduction capabilities, and do not support digital data recording and analysis, thus potentially lowering the quality of diagnosis. Therefore, the development of digital stethoscopes based on acoustic sensors, signal boosters, analog-to-digital (ADC) conversion, and microcontrollers is a promising solution. The research method included hardware design and device performance testing by comparing the results of heart rate measurements to the standard 12-lead ECG examination. The test was carried out on five male respondents with an age range of 26–46 years, and involved three medical personnel as examiners. The measurement results showed that the first respondent obtained a value of 85–90 bpm compared to ECG of 90–91 bpm, the second respondent 77–80 bpm compared to 79–81 bpm, the third respondent 80–85 bpm compared to 81–85 bpm, the fourth respondent 90–94 bpm compared to 90–92 bpm, and the fifth respondent 101–112 bpm compared to 100–105 bpm. Overall, the measurement difference was in the range of 1–7 bpm with a low average deviation, indicating a good level of accuracy and consistency between testers. In addition, digital stethoscopes are able to improve signal quality through noise amplification and filtering features, making it easier to identify heart sounds. 

Downloads

Download data is not yet available.

Author Biographies

  • zulfi chumaidi, Universitas PGRI Adi Buana Surabaya

    Electrical Engineering

  • Dwi Hastuti, Universitas PGRI Adi Buana Surabaya

    Electrical Engineering

  • Wildan Surya Wijaya, Universitas PGRI Adi Buana Surabaya

    Electrical Engineering

References

K. Boonprasert et al., “Survival analysis of confirmed elephant endotheliotropic herpes virus cases in Thailand from 2006 – 2018,” PLoS One, vol. 14, no. 7, p. e0219288, Jul. 2019, doi: 10.1371/journal.pone.0219288.

[2] K. Fuady, N. Nanda, and E. Zulisa, “The Digital Stethoscope with the Heart Rate Display: A Review and Its Implications for Learning,” Circuit: Jurnal Ilmiah Pendidikan Teknik Elektro, vol. 8, no. 2, p. 138, May 2024, doi: 10.22373/crc.v8i2.22096.

[3] A. A. Garanin, O. Y. Aydumova, A. O. Rubanenko, and E. G. Bibikova, “Digital stethoscope: a new era of auscultation,” Digital Diagnostics, vol. 5, no. 4, pp. 808–818, Nov. 2024, doi: 10.17816/DD632499.

[4] Y. Y. Ang, L. R. Aw, V. Koh, and R. X. Tan, “Characterization and cross-comparison of digital stethoscopes for telehealth remote patient auscultation,” Med. Nov. Technol. Devices, vol. 19, p. 100256, Sep. 2023, doi: 10.1016/j.medntd.2023.100256.

[5] F.-C. Goethe Doualla, G. Bediang, and C. Nganou-Gnindjio, “Evaluation of a digitally enhanced cardiac auscultation learning method: a controlled study,” BMC Med. Educ., vol. 21, no. 1, p. 380, Dec. 2021, doi: 10.1186/s12909-021-02807-4.

[6] M. E. Legget, M. Toh, A. Meintjes, S. Fitzsimons, G. Gamble, and R. N. Doughty, “Digital devices for teaching cardiac auscultation - a randomized pilot study,” Med. Educ. Online, vol. 23, no. 1, p. 1524688, Jan. 2018, doi: 10.1080/10872981.2018.1524688.

[7] C. T. Mesquita et al., “Digital Stethoscope as an Innovative Tool on the Teaching of Auscultatory Skills,” Arq. Bras. Cardiol., vol. 100, no. 2, pp. 187–189, 2013, doi: 10.5935/abc.20130033.

[8] N. Turner and S. Barton, “Cardiac Auscultation Using Artificial Intelligence on Different Devices,” Journal of Student Research, vol. 12, no. 4, Nov. 2023, doi: 10.47611/jsrhs.v12i4.5322.

[9] R. Prawira, S. Ismail, A. Johan, and R. Ismail, “Diagnostic Accuracy of a Wireless Stethoscope for Cardiac and Pulmonary Auscultation in Critically Ill Patients,” Mutiara Medika: Jurnal Kedokteran dan Kesehatan, vol. 26, no. 1, pp. 46–55, Jan. 2026, doi: 10.18196/mmjkk.v26i1.29519.

[10] B. Silverman and M. Balk, “Digital Stethoscope—Improved Auscultation at the Bedside,” Am. J. Cardiol., vol. 123, no. 6, pp. 984–985, Mar. 2019, doi: 10.1016/j.amjcard.2018.12.022.

[11] N. Saraya, J. McBride, K. Singh, O. Sohail, and P. J. Das, “Comparison of Auscultation Quality Using Contemporary Digital Stethoscopes,” JMIR Cardio, vol. 8, p. e54746, Nov. 2024, doi: 10.2196/54746.

[12] J. E. Mangole, E. Nurachmah, A. Waluyo, and M. Adam, “Penggunaan Stetoskop Elektronik pada Kelainan Katup Jantung,” Journal of Telenursing (JOTING), vol. 5, no. 2, pp. 3453–3460, Dec. 2023, doi: 10.31539/joting.v5i2.7756.

Published

2026-10-16

How to Cite

chumaidi, zulfi, Hastuti, D., & Surya Wijaya, W. (2026). Digital Stethoscope in Improving the Diagnostic Accuracy of Heart Auscultation: STETOSKOP DIGITAL DALAM MENINGKATKAN AKURASI DIAGNOSTIK AUSKULTASI JANTUNG. Jurnal Qua Teknika, 16(02), 43-53. https://doi.org/10.35457/quateknika.v16i02.5656